Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 45
Page 203
... covering maximum allowable spacing of gypsum , wood , and fiber insulation lath , see Section 4703 . For provisions covering maximum allowable spacing of supports for metal and wire lath on wood studs and rafters and method of ...
... covering maximum allowable spacing of gypsum , wood , and fiber insulation lath , see Section 4703 . For provisions covering maximum allowable spacing of supports for metal and wire lath on wood studs and rafters and method of ...
Page 204
... covering the ex- terior of outside walls , it shall be of the exterior type not less than three - eighths inch ( % " ) thick . Joints shall occur over framing members not less than two inches ( 2 " ) thick , unless wood or plywood ...
... covering the ex- terior of outside walls , it shall be of the exterior type not less than three - eighths inch ( % " ) thick . Joints shall occur over framing members not less than two inches ( 2 " ) thick , unless wood or plywood ...
Page 248
... covering . If Chapter 43 specifies , as fire - protective covering of the reinforcement , thicknesses of concrete greater than those given in this Section , then such greater thicknesses shall be used . For special requirements for ...
... covering . If Chapter 43 specifies , as fire - protective covering of the reinforcement , thicknesses of concrete greater than those given in this Section , then such greater thicknesses shall be used . For special requirements for ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength