Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 86
Page 82
... floor to any ceiling , beam , pipe , or similar construc- tion except for wall - mounted shelves , storage surfaces , racks , or cabinets . ( b ) Superficial Floor Area . Every dwelling unit shall have at least one room which shall have ...
... floor to any ceiling , beam , pipe , or similar construc- tion except for wall - mounted shelves , storage surfaces , racks , or cabinets . ( b ) Superficial Floor Area . Every dwelling unit shall have at least one room which shall have ...
Page 100
... floors in Subsection 2514 ( e ) . Not more than two mezzanine floors shall be in any room of a building . No mezzanine floor or floors shall cover more than 33 % per cent of the area of any room . Sec . 1805. Stairs and stair platforms ...
... floors in Subsection 2514 ( e ) . Not more than two mezzanine floors shall be in any room of a building . No mezzanine floor or floors shall cover more than 33 % per cent of the area of any room . Sec . 1805. Stairs and stair platforms ...
Page 394
International Conference of Building Officials. General Steel - Joisted Floors Wood Floors CHAPTER 31 - FLOOR CONSTRUCTION Sec . 3101. Floor construction shall be of materials and construction as specified under Occupancy in Part III and ...
International Conference of Building Officials. General Steel - Joisted Floors Wood Floors CHAPTER 31 - FLOOR CONSTRUCTION Sec . 3101. Floor construction shall be of materials and construction as specified under Occupancy in Part III and ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength