Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 55
Page 137
... Gypsum masonry is that form of Gypsum construction made with gypsum block or tile in which the Masonry units are laid and set in gypsum mortar . Gypsum masonry shall not be used in any bearing wall or where exposed di- rectly to the ...
... Gypsum masonry is that form of Gypsum construction made with gypsum block or tile in which the Masonry units are laid and set in gypsum mortar . Gypsum masonry shall not be used in any bearing wall or where exposed di- rectly to the ...
Page 470
... gypsum lath and perlite or vermiculite gypsum plaster each side 2124 24 Solid Neat Wood Fibered 51 Gypsum Plaster 34 " by No. 16 gauge cold - rolled channels , 12 " on center with 2.5 - pound flat metal lath applied to one face and tied ...
... gypsum lath and perlite or vermiculite gypsum plaster each side 2124 24 Solid Neat Wood Fibered 51 Gypsum Plaster 34 " by No. 16 gauge cold - rolled channels , 12 " on center with 2.5 - pound flat metal lath applied to one face and tied ...
Page 516
... gypsum wall- board shall be applied with fasteners of the type and size as required for the nonadhesive application of single - ply gypsum wallboard . Fastener spacings shall be in accordance with Table No. 47 - H . The face ply of gypsum ...
... gypsum wall- board shall be applied with fasteners of the type and size as required for the nonadhesive application of single - ply gypsum wallboard . Fastener spacings shall be in accordance with Table No. 47 - H . The face ply of gypsum ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength