Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 39
Page 506
... Lath 1 % " No. 13 gauge , 11⁄2 " Gypsum Lath " head , blued4 14 " No. 13 gauge , " head , blued4 5 5 4 7/8 16 34 5 5 56 56 1 % 16 34 4 ་ 4 47 47 Attach self - furring wire fabric lath to supports at furring device . " Perforated lath . ' ...
... Lath 1 % " No. 13 gauge , 11⁄2 " Gypsum Lath " head , blued4 14 " No. 13 gauge , " head , blued4 5 5 4 7/8 16 34 5 5 56 56 1 % 16 34 4 ་ 4 47 47 Attach self - furring wire fabric lath to supports at furring device . " Perforated lath . ' ...
Page 508
International Conference of Building Officials. Interior Lath ( Continued ) Exterior Lath ( Continued from page 501 ) Where electrical radiant heat cables are installed on ceil- ings , the stripping , if conductive , may be omitted a ...
International Conference of Building Officials. Interior Lath ( Continued ) Exterior Lath ( Continued from page 501 ) Where electrical radiant heat cables are installed on ceil- ings , the stripping , if conductive , may be omitted a ...
Page 509
... lath and attachments . Gypsum lath or gypsum board shall not be used , except that on horizontal supports of ceilings or roof soffits , it may be used as backing for metal lath or wire lath and portland cement plaster . Backing is not ...
... lath and attachments . Gypsum lath or gypsum board shall not be used , except that on horizontal supports of ceilings or roof soffits , it may be used as backing for metal lath or wire lath and portland cement plaster . Backing is not ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength