Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 75
Page 37
... located that the vertical distance from grade to the floor below is equal to or greater than the ver- tical distance from grade to ceiling . ( See " Story . " ) CENTRAL HEATING PLANT is comfort heating plant equipment installed in such ...
... located that the vertical distance from grade to the floor below is equal to or greater than the ver- tical distance from grade to ceiling . ( See " Story . " ) CENTRAL HEATING PLANT is comfort heating plant equipment installed in such ...
Page 60
... located over usable spaces , need not have one - hour fire - resistive protection . Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive con- struction . Group B ...
... located over usable spaces , need not have one - hour fire - resistive protection . Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive con- struction . Group B ...
Page 443
... located that any portion of the building can be reached therefrom with a hose not exceeding seventy - five feet ( 75 ' ) in length . ( d ) Location . In Groups A and B Occupancies , outlets shall be located as follows : On each side of ...
... located that any portion of the building can be reached therefrom with a hose not exceeding seventy - five feet ( 75 ' ) in length . ( d ) Location . In Groups A and B Occupancies , outlets shall be located as follows : On each side of ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength