Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 84
Page 126
... reinforced concrete bracing mem- bers or walls conforming with the requirements of Section 2632 of this Code . Reinforced concrete shear walls and reinforced concrete braced frames for all buildings shall conform to the requirements of ...
... reinforced concrete bracing mem- bers or walls conforming with the requirements of Section 2632 of this Code . Reinforced concrete shear walls and reinforced concrete braced frames for all buildings shall conform to the requirements of ...
Page 231
... concrete in pounds per ( Continued ) square inch . Compressive strength shall be determined by tests of standard six ... reinforced concrete . PRECAST CONCRETE , a plain or reinforced concrete element cast in other than its final ...
... concrete in pounds per ( Continued ) square inch . Compressive strength shall be determined by tests of standard six ... reinforced concrete . PRECAST CONCRETE , a plain or reinforced concrete element cast in other than its final ...
Page 583
... reinforced concrete . For masonry For stucco For prestressed concrete . For T - beams , reinforced concrete . For two - way slabs , reinforced concrete . For web ( diagonal tension ) , concrete . Inspection Lateral Minimum in flexural ...
... reinforced concrete . For masonry For stucco For prestressed concrete . For T - beams , reinforced concrete . For two - way slabs , reinforced concrete . For web ( diagonal tension ) , concrete . Inspection Lateral Minimum in flexural ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength