... SPACE FRAME is a three - dimensional structural system composed of interconnected members , other than bearing walls ... SPACE FRAME - MOMENT RESISTING is a vertical load carrying space frame in which the members and joints are capable ...
... SPACE FRAME is a three - dimensional structural system composed of interconnected members , other than bearing walls ... SPACE FRAME - MOMENT RESISTING is a vertical load carrying space frame in which the members and joints are capable ...
Page 121
... space frame shall resist the total required lateral forces ( 3 ) The ductile moment resisting space frame shall have the capacity to resist not less than 25 per cent of the required lateral force Buildings with a ductile moment resisting ...
... space frame shall resist the total required lateral forces ( 3 ) The ductile moment resisting space frame shall have the capacity to resist not less than 25 per cent of the required lateral force Buildings with a ductile moment resisting ...
Page 125
... space frame capable of resist- ing not less than 25 per cent of the required seismic force for the structure as a whole . All buildings designed with a hori- zontal force factor " K " of 0.67 or 0.80 shall have a ductile moment ...
... space frame capable of resist- ing not less than 25 per cent of the required seismic force for the structure as a whole . All buildings designed with a hori- zontal force factor " K " of 0.67 or 0.80 shall have a ductile moment ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength