Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 46
Page 61
... street not less Property than twenty feet ( 20 ' ) in width . The access to the public street shall be a minimum twenty - foot ( 20 ' ) wide right - of- way unobstructed and maintained only as access to the public street . The main ...
... street not less Property than twenty feet ( 20 ' ) in width . The access to the public street shall be a minimum twenty - foot ( 20 ' ) wide right - of- way unobstructed and maintained only as access to the public street . The main ...
Page 63
... street not less than twenty feet ( 20 ' ) in width . The access to the public street shall be a minimum twenty - foot ( 20 ′ ) wide right - of - way unobstructed and maintained only as access to the public street . At least one required ...
... street not less than twenty feet ( 20 ' ) in width . The access to the public street shall be a minimum twenty - foot ( 20 ′ ) wide right - of - way unobstructed and maintained only as access to the public street . At least one required ...
Page 492
... STREETS AND PROJECTIONS OVER PUBLIC PROPERTY CHAPTER 44 - PROTECTION OF PEDESTRIANS DURING CONSTRUCTION OR DEMOLITION Sec . 4401. No person shall use or occupy a street , alley , or public sidewalk for the performance of work under a ...
... STREETS AND PROJECTIONS OVER PUBLIC PROPERTY CHAPTER 44 - PROTECTION OF PEDESTRIANS DURING CONSTRUCTION OR DEMOLITION Sec . 4401. No person shall use or occupy a street , alley , or public sidewalk for the performance of work under a ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength