Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 94
Page 21
... structure within the city , except work located primarily in a public way , public utility towers and poles ... structure , such building or structure shall be made to conform to the requirements for new buildings or structures . ( c ) ...
... structure within the city , except work located primarily in a public way , public utility towers and poles ... structure , such building or structure shall be made to conform to the requirements for new buildings or structures . ( c ) ...
Page 22
... structures may be made to such building or structure within any 12 - month period without making the entire building or structure comply . The new construction shall conform to the requirements of this Code for a new building of like ...
... structures may be made to such building or structure within any 12 - month period without making the entire building or structure comply . The new construction shall conform to the requirements of this Code for a new building of like ...
Page 229
... structure . A load test of a structure shall not be made until the por- tion subjected to load is at least 56 days old , unless the owner of the structure agrees to the test being made at an earlier age . When the whole structure is not ...
... structure . A load test of a structure shall not be made until the por- tion subjected to load is at least 56 days old , unless the owner of the structure agrees to the test being made at an earlier age . When the whole structure is not ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength