Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 20
Page 48
... Division 1. Any assembly building with a stage and an occupant load of less than 1000 in the building . Division 2. Any assembly building without a stage and having an occupant load of 300 or more in the building . Division 3. Any ...
... Division 1. Any assembly building with a stage and an occupant load of less than 1000 in the building . Division 2. Any assembly building without a stage and having an occupant load of 300 or more in the building . Division 3. Any ...
Page 53
... Division 1 : Mental hospitals , jails , prisons , reformatories , Defined houses of correction , and buildings where personal liberties of inmates are similarly restrained . Division 2 : Nurseries for the full time care of children ...
... Division 1 : Mental hospitals , jails , prisons , reformatories , Defined houses of correction , and buildings where personal liberties of inmates are similarly restrained . Division 2 : Nurseries for the full time care of children ...
Page 55
... Division 1. Storage and handling of hazardous and highly Occupancies flammable or explosive materials other than flammable Defined liquids . Division 2. Storage and handling of Class I , II and III flammable liquids , as specified in ...
... Division 1. Storage and handling of hazardous and highly Occupancies flammable or explosive materials other than flammable Defined liquids . Division 2. Storage and handling of Class I , II and III flammable liquids , as specified in ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood