Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 19
Page 66
International Conference of Building Officials, Pacific Coast Building Officials Conference. General Restrictions in Fire Zone No. 1 PART IV REQUIREMENTS BASED ON LOCATION IN FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES • Sec . 1601.
International Conference of Building Officials, Pacific Coast Building Officials Conference. General Restrictions in Fire Zone No. 1 PART IV REQUIREMENTS BASED ON LOCATION IN FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES • Sec . 1601.
Page 67
International Conference of Building Officials, Pacific Coast Building Officials Conference. in area need not be fire protected provided they are locat- Restrictions ed twenty feet ( 20 ' ) from adjacent property lines . in Fire Zone 2 ...
International Conference of Building Officials, Pacific Coast Building Officials Conference. in area need not be fire protected provided they are locat- Restrictions ed twenty feet ( 20 ' ) from adjacent property lines . in Fire Zone 2 ...
Page 68
... Fire Zone No. 3 . PART V REQUIREMENTS BASED ON TYPES OF CONSTRUCTION - CHAPTER 68 Sections 1603-1604 UNIFORM BUILDING CODE Restrictions in Fire Zone No 1 1603 Restrictions in Fire Zone No 2 Restrictions in Fire Zone No 3 888886.
... Fire Zone No. 3 . PART V REQUIREMENTS BASED ON TYPES OF CONSTRUCTION - CHAPTER 68 Sections 1603-1604 UNIFORM BUILDING CODE Restrictions in Fire Zone No 1 1603 Restrictions in Fire Zone No 2 Restrictions in Fire Zone No 3 888886.
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood