Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 91
Page 7
... Allowable Location on Property Exit Facilities CHAPTER 11 . SEC . 1101 . 1102 . 1103 . 1104 . 1105 . Light , Ventilation , and Sanitation 1106 . 1107 . 1108 . Special Hazards CHAPTER 12 . SEC . 1201 . 1202 . Enclosure of Vertical ...
... Allowable Location on Property Exit Facilities CHAPTER 11 . SEC . 1101 . 1102 . 1103 . 1104 . 1105 . Light , Ventilation , and Sanitation 1106 . 1107 . 1108 . Special Hazards CHAPTER 12 . SEC . 1201 . 1202 . Enclosure of Vertical ...
Page 102
... allowable stress , by dead load , or by live load applied continuously or cumulatively for more than 10 years such as from fixed equipment , tanks and warehouse storage , the working stresses used in the design shall not exceed 90 per ...
... allowable stress , by dead load , or by live load applied continuously or cumulatively for more than 10 years such as from fixed equipment , tanks and warehouse storage , the working stresses used in the design shall not exceed 90 per ...
Page 109
... allowable unit axial stress permitted for members act- ing solely as a column ( see Table No. 25 - A and Sec- tion 2505 ) . M = total bending moment in inch pounds resulting from load causing flexure . S section modulus ( in inches ...
... allowable unit axial stress permitted for members act- ing solely as a column ( see Table No. 25 - A and Sec- tion 2505 ) . M = total bending moment in inch pounds resulting from load causing flexure . S section modulus ( in inches ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood