Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 58
Page 132
... distance be- tween parallel bars , except in columns , shall be equal to the nominal diameter of the bars . The minimum clear distance between bars and forms shall be the diameter of round bars and one - and - one - half times the side ...
... distance be- tween parallel bars , except in columns , shall be equal to the nominal diameter of the bars . The minimum clear distance between bars and forms shall be the diameter of round bars and one - and - one - half times the side ...
Page 169
... DISTANCES MINIMUM EDGE DISTANCE ( INCHES ) FOR PUNCHED HOLES RIVET DIAMETER ( Inches ) In Sheared In Rolled Edge Edge of Plates | In Rolled Edge of Structural Shapes **** 1 8 34 118 1 % 14 18 1 11/2 14 1 % * 1 134 11/2 14 1 % 2 13/4 12 ...
... DISTANCES MINIMUM EDGE DISTANCE ( INCHES ) FOR PUNCHED HOLES RIVET DIAMETER ( Inches ) In Sheared In Rolled Edge Edge of Plates | In Rolled Edge of Structural Shapes **** 1 8 34 118 1 % 14 18 1 11/2 14 1 % * 1 134 11/2 14 1 % 2 13/4 12 ...
Page 172
... distance between the lines of rivets connecting them to the segments of the members , and the rivet pitch shall be not more than six diameters and the tie plates shall be connected to each segment by at least three rivets . In welded ...
... distance between the lines of rivets connecting them to the segments of the members , and the rivet pitch shall be not more than six diameters and the tie plates shall be connected to each segment by at least three rivets . In welded ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood