Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 48
Page 6
... Enclosure of Vertical Openings 46 47 607. Fire - Extinguishing Systems 47 608. Special Hazards 47 609 . Exceptions and Deviations 47 CHAPTER 7 . SEC . 701 . Requirements for Group B Occupancies Group B Occupancies Defined 702 ...
... Enclosure of Vertical Openings 46 47 607. Fire - Extinguishing Systems 47 608. Special Hazards 47 609 . Exceptions and Deviations 47 CHAPTER 7 . SEC . 701 . Requirements for Group B Occupancies Group B Occupancies Defined 702 ...
Page 81
... Enclosure walls for elevator shafts , vent shafts , Enclosure and similar vertical openings shall be of not less than one- of Vertical hour fire - resistive construction , except that chutes and Openings dumb - waiter shafts with a ...
... Enclosure walls for elevator shafts , vent shafts , Enclosure and similar vertical openings shall be of not less than one- of Vertical hour fire - resistive construction , except that chutes and Openings dumb - waiter shafts with a ...
Page 316
... ENCLOSURE OF VERTICAL OPENINGS ( see OCCUPANCY , TYPES OF CONSTRUCTION , and STAIRS AND EXITS ) For elevators 3002 For stairs and ramps 3308 Miscellaneous openings 3003 Required , when 3001 Smokeproof enclosure , when 3309 Through ...
... ENCLOSURE OF VERTICAL OPENINGS ( see OCCUPANCY , TYPES OF CONSTRUCTION , and STAIRS AND EXITS ) For elevators 3002 For stairs and ramps 3308 Miscellaneous openings 3003 Required , when 3001 Smokeproof enclosure , when 3309 Through ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood