Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 5
Page 303
... fire - resistance rating of not less than one hour . Such openings shall be equipped with fire doors or other approved devices of a type required for Class " B " openings . ( e ) Other Types . Incinerators of types other than those ...
... fire - resistance rating of not less than one hour . Such openings shall be equipped with fire doors or other approved devices of a type required for Class " B " openings . ( e ) Other Types . Incinerators of types other than those ...
Page 315
... Fire Zones No. 1 , 2 , and 3 For occupancies ( see OCCUPANCY ) For occupancy groups 2708-2710 , incl . .2508-2521 ... rating Fire - resistive - classification , design , hanging Fire - resistive - when required ( see under OCCUPANCY ...
... Fire Zones No. 1 , 2 , and 3 For occupancies ( see OCCUPANCY ) For occupancy groups 2708-2710 , incl . .2508-2521 ... rating Fire - resistive - classification , design , hanging Fire - resistive - when required ( see under OCCUPANCY ...
Page 338
... Fire - resistive 4304 Foundation 2805 Hollow masonry - bearing partitions 2404 ( b ) , 2408 Hollow masonry - fire - resistive classification ... rating 4304 Solid masonry - foundation walls 2805 Solid masonry - general provisions 2405 Solid ...
... Fire - resistive 4304 Foundation 2805 Hollow masonry - bearing partitions 2404 ( b ) , 2408 Hollow masonry - fire - resistive classification ... rating 4304 Solid masonry - foundation walls 2805 Solid masonry - general provisions 2405 Solid ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood