Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 22
Page 213
... flue gases as they enter the flue is above 1500 ° F. to be measured at the outlet of the appliance or at the outlet of the draft hood attached to the appliance . APPLIANCES , LOW HEAT , are any installation or equip- ment in which the ...
... flue gases as they enter the flue is above 1500 ° F. to be measured at the outlet of the appliance or at the outlet of the draft hood attached to the appliance . APPLIANCES , LOW HEAT , are any installation or equip- ment in which the ...
Page 218
... Flues or Vents struction more than 90 ° F. above normal room temperature when measured with a mercury thermometer or convention- al bead - type thermocouples . Flue or vent piping requiring a clearance greater than one inch ( 1 " ) to ...
... Flues or Vents struction more than 90 ° F. above normal room temperature when measured with a mercury thermometer or convention- al bead - type thermocouples . Flue or vent piping requiring a clearance greater than one inch ( 1 " ) to ...
Page 220
... flue or vent unless the com- mon smoke pipe and flue or vent is of sufficient size to serve all the appliances thus connected . The smoke pipe of a heat- ing appliance shall not be connected into the flue or vent of an incinerator which ...
... flue or vent unless the com- mon smoke pipe and flue or vent is of sufficient size to serve all the appliances thus connected . The smoke pipe of a heat- ing appliance shall not be connected into the flue or vent of an incinerator which ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood