Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 37
Page 84
... FOOT TRIBUTARY LOADED AREA IN SQUARE FEET FOR ANY 0 to 200 201 to 600 Over 600 STRUCTURAL MEMBER Roof member Flat or rise less than 4 inches per foot . Arch or dome with rise less than 1 % of the span . Rise 4 inches per foot to less ...
... FOOT TRIBUTARY LOADED AREA IN SQUARE FEET FOR ANY 0 to 200 201 to 600 Over 600 STRUCTURAL MEMBER Roof member Flat or rise less than 4 inches per foot . Arch or dome with rise less than 1 % of the span . Rise 4 inches per foot to less ...
Page 85
... foot of area supported by the member L - Unit live load per square foot of area supported by the member For storage live loads exceeding 100 pounds per square foot , no reduction shall be made except design live loads on columns may be ...
... foot of area supported by the member L - Unit live load per square foot of area supported by the member For storage live loads exceeding 100 pounds per square foot , no reduction shall be made except design live loads on columns may be ...
Page 178
... FOOT INCREASE IN VALUE FOR EACH FOOT OF DEPTH THAT FOOTING IS BELOW MINIMUM DEPTH . POUNDS PER SQUARE FOOT MAXIMUM VALUE . POUNDS PER SQUARE FOOT * These values are for footings one foot in width and may be increased in direct ...
... FOOT INCREASE IN VALUE FOR EACH FOOT OF DEPTH THAT FOOTING IS BELOW MINIMUM DEPTH . POUNDS PER SQUARE FOOT MAXIMUM VALUE . POUNDS PER SQUARE FOOT * These values are for footings one foot in width and may be increased in direct ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood