Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 77
Page 89
... MASONRY WALLS MAXIMUM RATIO TYPE OF MASONRY UNSUPPORTED HEIGHT OR LENGTH TO THICKNESS NOMINAL MINIMUM THICKNESS ( Inches ) Plain Solid Masonry Grouted Brick Masonry Hollow Unit Masonry Cavity Wall Masonry Stone Masonry ( Ashlar ) ...
... MASONRY WALLS MAXIMUM RATIO TYPE OF MASONRY UNSUPPORTED HEIGHT OR LENGTH TO THICKNESS NOMINAL MINIMUM THICKNESS ( Inches ) Plain Solid Masonry Grouted Brick Masonry Hollow Unit Masonry Cavity Wall Masonry Stone Masonry ( Ashlar ) ...
Page 95
... Masonry masonry is designed under limitations and stresses speci- ( Cont'd . ) fied for unreinforced masonry . No required vertical rein- forcement shall be less than three - eighths inch ( % " ) in diameter . The required horizontal ...
... Masonry masonry is designed under limitations and stresses speci- ( Cont'd . ) fied for unreinforced masonry . No required vertical rein- forcement shall be less than three - eighths inch ( % " ) in diameter . The required horizontal ...
Page 96
... Masonry Stone Masonry Gypsum Masonry compressive strength of the units . The value of f ' , may be determined by tests as provided in Section 2407 ( a ) based on ... Masonry 2409 Cavity Wall Masonry 2410 Stone Masonry 2411 Gypsum Masonry.
... Masonry Stone Masonry Gypsum Masonry compressive strength of the units . The value of f ' , may be determined by tests as provided in Section 2407 ( a ) based on ... Masonry 2409 Cavity Wall Masonry 2410 Stone Masonry 2411 Gypsum Masonry.
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood