Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 63
Page 6
... Occupancies Group B Occupancies Defined 702. Construction , Height and Area 703 . Allowable Location on Property 704 . 705 . 706 . Exit Facilities Light , Ventilation , and Sanitation Enclosure of Vertical Openings 707. Fire ...
... Occupancies Group B Occupancies Defined 702. Construction , Height and Area 703 . Allowable Location on Property 704 . 705 . 706 . Exit Facilities Light , Ventilation , and Sanitation Enclosure of Vertical Openings 707. Fire ...
Page 7
... Occupancies Group F Occupancies Defined Construction , Height and Area Allowable Location on Property Exit Facilities CHAPTER 11 . SEC . 1101 . 1102 . 1103 . 1104 . 1105 . Light , Ventilation , and Sanitation 1106 . 1107 . 1108 ...
... Occupancies Group F Occupancies Defined Construction , Height and Area Allowable Location on Property Exit Facilities CHAPTER 11 . SEC . 1101 . 1102 . 1103 . 1104 . 1105 . Light , Ventilation , and Sanitation 1106 . 1107 . 1108 ...
Page 48
International Conference of Building Officials, Pacific Coast Building Officials Conference. Group B Occupancies Defined Construction , Height and Ares Allowable CHAPTER 7- REQUIREMENTS FOR GROUP B OCCUPANCIES Sec . 701. Group B occupancies ...
International Conference of Building Officials, Pacific Coast Building Officials Conference. Group B Occupancies Defined Construction , Height and Ares Allowable CHAPTER 7- REQUIREMENTS FOR GROUP B OCCUPANCIES Sec . 701. Group B occupancies ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood