Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 89
Page 49
... specified in Chapter 33 . ( b ) Amusement Structures . Stairs and exits for Division 4 amusement structures shall be provided as specified in Chapter 33 , subject to the approval of the Building Official . Exit signs shall be installed ...
... specified in Chapter 33 . ( b ) Amusement Structures . Stairs and exits for Division 4 amusement structures shall be provided as specified in Chapter 33 , subject to the approval of the Building Official . Exit signs shall be installed ...
Page 78
... specified in Sec . 2521 ( k ) . Sec . 2004 ( a ) . General . Floors may be constructed as specified in Chapter 26 for concrete , Chapter 24 for masonry , Chapter 25 for wood , and Chapter 27 for steel or iron . Wood joists , beams and ...
... specified in Sec . 2521 ( k ) . Sec . 2004 ( a ) . General . Floors may be constructed as specified in Chapter 26 for concrete , Chapter 24 for masonry , Chapter 25 for wood , and Chapter 27 for steel or iron . Wood joists , beams and ...
Page 189
... specified in Sections 3102 and 3103 . Fire - resistive standards of floor construction are specified in Section 4305 . Sec . 3102. Concrete slab floors shall be not less than two Concrete inches ( 2 " ) thick . Topping when poured ...
... specified in Sections 3102 and 3103 . Fire - resistive standards of floor construction are specified in Section 4305 . Sec . 3102. Concrete slab floors shall be not less than two Concrete inches ( 2 " ) thick . Topping when poured ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood