Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 27
Page 197
... tile securely fastened with copper nails or copper wire ; provided that for roofs not exceeding a rise of eight inches ( 8 " ) in twelve inches ( 12 " ) , galvanized iron naits may be used , and provided further that tile with projec ...
... tile securely fastened with copper nails or copper wire ; provided that for roofs not exceeding a rise of eight inches ( 8 " ) in twelve inches ( 12 " ) , galvanized iron naits may be used , and provided further that tile with projec ...
Page 244
... Tile , Wall 29 Clay Plastered Bearing Standard 24-7 ) TABLE NO . 43 - B ( Continued ) 4. Minimum Finished Thickness face to face ( including plaster where mentioned ) in inches 4 - hr . 3 - hr . 2 - hr . 8 1 - hr . 4 * 9 5 * 12 10 8 9 ...
... Tile , Wall 29 Clay Plastered Bearing Standard 24-7 ) TABLE NO . 43 - B ( Continued ) 4. Minimum Finished Thickness face to face ( including plaster where mentioned ) in inches 4 - hr . 3 - hr . 2 - hr . 8 1 - hr . 4 * 9 5 * 12 10 8 9 ...
Page 279
... tile , laid Timber- Fir , dry Fir , wet Oak Water , fresh at 60 degrees Fahrenheit Lbs . Per Weights of Cu . Ft ... tile ( one side ) 5 2 " hollow clay tile 13 3 " hollow clay tile 16 4 " hollow clay tile 5 " hollow clay tile 6 " hollow ...
... tile , laid Timber- Fir , dry Fir , wet Oak Water , fresh at 60 degrees Fahrenheit Lbs . Per Weights of Cu . Ft ... tile ( one side ) 5 2 " hollow clay tile 13 3 " hollow clay tile 16 4 " hollow clay tile 5 " hollow clay tile 6 " hollow ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood