Uniform Building Code, Volume 1Pacific Coast Building Officials Conference, 1952 - Building laws |
From inside the book
Results 1-3 of 55
Page 111
... values shall be reduced one - quarter . In locations " usually wet , " tabulated bolt values shall be reduced one - third . ( h ) Definition of Seasoned Lumber . " Seasoned lumber , " for the purpose of this Section , is defined as ...
... values shall be reduced one - quarter . In locations " usually wet , " tabulated bolt values shall be reduced one - third . ( h ) Definition of Seasoned Lumber . " Seasoned lumber , " for the purpose of this Section , is defined as ...
Page 162
... values of l / r not greater than 120 ....... 12 .17,000 — 0.485 For axially loaded columns ( main members ) with values of l / r 18,000 greater than 120 12 1 + { 1.8 200r 18,000,2 For axially loaded columns ( bracing and other secondary ...
... values of l / r not greater than 120 ....... 12 .17,000 — 0.485 For axially loaded columns ( main members ) with values of l / r 18,000 greater than 120 12 1 + { 1.8 200r 18,000,2 For axially loaded columns ( bracing and other secondary ...
Page 178
... VALUE PERMISSIBLE IF FOOTING IS AT MINIMUM DEPTH . POUNDS PER SQUARE FOOT INCREASE IN VALUE FOR EACH FOOT OF DEPTH THAT FOOTING IS BELOW MINIMUM DEPTH . POUNDS PER SQUARE FOOT MAXIMUM VALUE . POUNDS PER SQUARE FOOT * These values are ...
... VALUE PERMISSIBLE IF FOOTING IS AT MINIMUM DEPTH . POUNDS PER SQUARE FOOT INCREASE IN VALUE FOR EACH FOOT OF DEPTH THAT FOOTING IS BELOW MINIMUM DEPTH . POUNDS PER SQUARE FOOT MAXIMUM VALUE . POUNDS PER SQUARE FOOT * These values are ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 33 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
appliance approved asbestos bars beams bolt brick Building Official building or structure ceiling cement cent Chimneys clearance Code column combustible compression compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone flammable liquids floor flue or vent foot four inches furnaces girders Grade grain Group grout gypsum heaters height horizontal incombustible materials installed interior joints joists lath least live load located lumber masonry metal minimum mortar occupant load one-half inch one-hour fire-resistive construction partitions permitted pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets roof shear six inches slab smoke pipe solid space specified in Chapter specified in Section square feet square inch Stairs stairway standpipes steel structural steel studs Subsection Table thickness twenty feet 20 TYPES OF CONSTRUCTION U.B.C. Standard ventilation width wire wood