Physical Principles and Techniques of Protein Chemistry, Part 2Sydney J. Leach, Sidney J. Leach Physical Principles and Techniques of Protein Chemistry, Part B deals with the theories and application of selected physical methods in protein chemistry evaluation. This book is divided into seven chapters that cover the ultracentrifugal analysis, light scattering, infrared (IR) methods, nuclear magnetic resonance (NMR) spectroscopy, and differential thermal analysis of protein properties. This text first describes the fundamental ideas and methodology of sedimentation analysis of ideal noninteracting solutes and the problems of nonideality and solute-solute interaction. This book then deals ... |
From inside the book
Results 1-3 of 25
Page 45
... Column , 1 mm Column , Zero Meniscus Concentration ( High Speed ) Methods a . 3 mm Column ( Van Holde and Baldwin , 1958 ) . In this method a column of solution 3 mm long with a volume of about 0.1 ml ( Fig . 16 ) and a concentration of ...
... Column , 1 mm Column , Zero Meniscus Concentration ( High Speed ) Methods a . 3 mm Column ( Van Holde and Baldwin , 1958 ) . In this method a column of solution 3 mm long with a volume of about 0.1 ml ( Fig . 16 ) and a concentration of ...
Page 51
... Column . It can be shown ( Richards and Schachman , 1959 ) that for a sector - shaped cell the absolute fringe number at the upper meniscus j ( a ) is given by j ( a ) = jo — [ xs2 ( Aj « ‚ ) — [ „ * x2dj ] / ( xs2 — xa2 ) - - ( 36 ) If ...
... Column . It can be shown ( Richards and Schachman , 1959 ) that for a sector - shaped cell the absolute fringe number at the upper meniscus j ( a ) is given by j ( a ) = jo — [ xs2 ( Aj « ‚ ) — [ „ * x2dj ] / ( xs2 — xa2 ) - - ( 36 ) If ...
Page 87
... column height is greater than that of the solution ; when the cell is run in the centrifuge , solvent will be transferred into the solution sector until the column heights are iden- tical . In this way problems caused by differential ...
... column height is greater than that of the solution ; when the cell is run in the centrifuge , solvent will be transferred into the solution sector until the column heights are iden- tical . In this way problems caused by differential ...
Contents
Ultracentrifugal Analysis | 10 |
Light Scattering | 12 |
Osmotic Pressure | 13 |
Copyright | |
31 other sections not shown
Other editions - View all
Common terms and phrases
absorption acid angle axial ratio axis band beam binding Biol Bradbury Brice calculated capillary centrifugal chain Chem chemical shifts column complex component concentration dependence constant copper(II denaturation density gradient determined diffusion dilution Doty effect ellipsoid equation experiments extrapolation filters Fraser frequency fringe groups Gurd Holtzer hydrogen increment instrument interaction intrinsic viscosity Kirkwood length light scattering light-scattering linear macromolecule maximum measured meniscus method molecular weight molecule Natl observed obtained optical density optical system parameters partial specific volume particle peak photographic Phys plate plateau plot Polymer Sci Proc procedure protein solution protons radius random coil Rayleigh reference refractive index refractive index increment residues resonance rotation rotor sample Schachman schlieren Section sedimentation coefficient sedimentation equilibrium shearing stress shown in Fig slit solvent spectra spectrum speed structure synthetic boundary Tanford technique temperature Timasheff tion transmittance tube ultracentrifuge values Vinograd viscometer zero Zimm zone