Uniform Building CodeInternational Conference of Building Officials, 1988 - Building laws |
From inside the book
Results 1-3 of 82
Page 55
... Division 1 Occu- pancy , located in the basement or first story below a Group B , Division 3 open parking garage , as defined in Section 709 , may be classified as a separate and distinct building for the purpose of determining the type ...
... Division 1 Occu- pancy , located in the basement or first story below a Group B , Division 3 open parking garage , as defined in Section 709 , may be classified as a separate and distinct building for the purpose of determining the type ...
Page 819
... division and which house Group B , Division 2 offices or Group R , Division 1 Occupancies , each having floors used for human occu- pancy located more than 75 feet above the lowest level of fire department vehicle access . General Sec ...
... division and which house Group B , Division 2 offices or Group R , Division 1 Occupancies , each having floors used for human occu- pancy located more than 75 feet above the lowest level of fire department vehicle access . General Sec ...
Page 833
... DIVISION 3 OCCUPANCIES Sec . 1221. ( a ) Purpose . The purpose of this division is to provide minimum standards for the protection of life , limb , health , property , environment and for the safety and welfare of the consumer , general ...
... DIVISION 3 OCCUPANCIES Sec . 1221. ( a ) Purpose . The purpose of this division is to provide minimum standards for the protection of life , limb , health , property , environment and for the safety and welfare of the consumer , general ...
Contents
Organization and Enforcement | 5 |
Part IIDefinitions and Abbreviations | 20 |
Requirements for Group A Occupancies | 50 |
Copyright | |
97 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved axial load bars beam bending bolts building official Chapter column compression members compressive strength compressive stress concrete conform corridor dead load Decking diameter diaphragm Division doors edge exceed exit exterior walls factor fire fire-resistive rating flange floor forces Formula framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located masonry materials maximum metal minimum modulus of elasticity nails noncombustible occupant load openings panel particleboard percent permitted perpendicular plaster plywood portland cement pounds per square prestressed protected ratio requirements of Section resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab smoke detector space span specified in Section splices square feet square inches stairway steel studs surface Table tensile tension thickness Type U.B.C. Standard values vertical wallboard welds width wire wood yield strength