Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 93
Page 1-205
... Section 1612.3 , in accordance with the applicable requirements of Section 2305 . 2301.2.2 Conventional light - frame construction . The design and construction of conventional light - frame wood structures shall be in accordance with ...
... Section 1612.3 , in accordance with the applicable requirements of Section 2305 . 2301.2.2 Conventional light - frame construction . The design and construction of conventional light - frame wood structures shall be in accordance with ...
Page 1-336
... Section 1515.2 for specific requirements . 2Board and batten leveling system must be firestopped in accordance with Section 1516.3 . 3One layer 18 - inch ( 457 mm ) Type 30 nonperforated felt interlaced between shake courses required ...
... Section 1515.2 for specific requirements . 2Board and batten leveling system must be firestopped in accordance with Section 1516.3 . 3One layer 18 - inch ( 457 mm ) Type 30 nonperforated felt interlaced between shake courses required ...
Page 1-401
... accordance with Sections 3107.1 and 3108.1 . SECTION 3105 — MANUFACTURED STRUCTURES New or replacement manufactured structures located in any flood hazard zone shall be located in accordance with the applicable ele- vation requirements of ...
... accordance with Sections 3107.1 and 3108.1 . SECTION 3105 — MANUFACTURED STRUCTURES New or replacement manufactured structures located in any flood hazard zone shall be located in accordance with the applicable ele- vation requirements of ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood