Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 68
Page 1-67
... AGGREGATE , is concrete made with aggregates of expanded clay , shale , slag or slate or sint- ered fly ash or any natural lightweight aggregate meeting ASTM C 330 and possessing equivalent fire - resistive properties and weighing 85 to ...
... AGGREGATE , is concrete made with aggregates of expanded clay , shale , slag or slate or sint- ered fly ash or any natural lightweight aggregate meeting ASTM C 330 and possessing equivalent fire - resistive properties and weighing 85 to ...
Page 1-76
... aggregate concrete , members 6 " by 6 " ( 152 mm by 152 mm ) or greater ( not including sandstone , granite and siliceous gravel ) .1 Carbonate , lightweight and sand - lightweight aggregate concrete , members 8 " by 8 " ( 203 mm by 203 ...
... aggregate concrete , members 6 " by 6 " ( 152 mm by 152 mm ) or greater ( not including sandstone , granite and siliceous gravel ) .1 Carbonate , lightweight and sand - lightweight aggregate concrete , members 8 " by 8 " ( 203 mm by 203 ...
Page 1-78
... aggregate concrete Beams or girders 37 47 21/2 11/2 in prestressed Solid slabs 2 11/2 concrete5 Carbonate , lightweight , sand - lightweight and siliceous aggregate concrete Unrestrained members : 2 11/2 Solid slabs8 4-1.1 4. Bonded or ...
... aggregate concrete Beams or girders 37 47 21/2 11/2 in prestressed Solid slabs 2 11/2 concrete5 Carbonate , lightweight , sand - lightweight and siliceous aggregate concrete Unrestrained members : 2 11/2 Solid slabs8 4-1.1 4. Bonded or ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood