... applied full length vertically , second layer applied horizontally or vertically . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers 1/2 " ( 12.7 mm ) regular gypsum wallboard applied vertically or ...
... applied full length vertically , second layer applied horizontally or vertically . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers 1/2 " ( 12.7 mm ) regular gypsum wallboard applied vertically or ...
Page 1-264
... applied over base coats that have been in place for the time periods set forth in Table 25 - F . The third or finish coat shall be applied with sufficient material and pressure to bond to and to cover the brown coat and shall be of suf ...
... applied over base coats that have been in place for the time periods set forth in Table 25 - F . The third or finish coat shall be applied with sufficient material and pressure to bond to and to cover the brown coat and shall be of suf ...
Page 1-336
... applied over an existing asphalt or wood shingle roof . Asphalt shingles applied over wood shingles shall not have less than Type 30 nonperforated felt underlayment installed prior to reroofing . 2. Wood shakes . Not more than one ...
... applied over an existing asphalt or wood shingle roof . Asphalt shingles applied over wood shingles shall not have less than Type 30 nonperforated felt underlayment installed prior to reroofing . 2. Wood shakes . Not more than one ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood