Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 91
Page 1-208
... approved agency . Foundation cedar or No. 2 Foun- dation redwood marked or branded by an approved agency may be used for sills in territories subject to moderate hazard , where ter- mite damage is not frequent and when specifically approved ...
... approved agency . Foundation cedar or No. 2 Foun- dation redwood marked or branded by an approved agency may be used for sills in territories subject to moderate hazard , where ter- mite damage is not frequent and when specifically approved ...
Page 1-276
... approved au- tomatic sprinkler system complying with UBC Standard 9-1 or 9-3 . 5. The aggregate area of skylights installed in the roof shall not exceed 331/3 percent of the floor area of the room or space shel- tered by the roof when ...
... approved au- tomatic sprinkler system complying with UBC Standard 9-1 or 9-3 . 5. The aggregate area of skylights installed in the roof shall not exceed 331/3 percent of the floor area of the room or space shel- tered by the roof when ...
Page 1-416
... approved location when required by the fire depart- ment . 3418.1.10 Automatic elevator recall system . Elevators shall be equipped with an approved automatic recall system as required by Section 403.7 , Item 2 . 3418.1.11 Unlocked ...
... approved location when required by the fire depart- ment . 3418.1.10 Automatic elevator recall system . Elevators shall be equipped with an approved automatic recall system as required by Section 403.7 , Item 2 . 3418.1.11 Unlocked ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood