... butt joints along studs . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers of 3/8 " ( 9.5 mm ) regular gypsum wallboard ' each side , 4d cooler19 or wallboard 19 nails at 8 " ( 203 mm ) on center first ...
... butt joints along studs . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers of 3/8 " ( 9.5 mm ) regular gypsum wallboard ' each side , 4d cooler19 or wallboard 19 nails at 8 " ( 203 mm ) on center first ...
Page 1-209
... joints between members . Depending on local experience , such members may in ... butt section of not less than 7/16 inch ( 11 mm ) and a tip thickness of not ... joints shall occur over framing members and shall be protected with a contin ...
... joints between members . Depending on local experience , such members may in ... butt section of not less than 7/16 inch ( 11 mm ) and a tip thickness of not ... joints shall occur over framing members and shall be protected with a contin ...
Page 1-210
... joints shall occur over framing members and shall be covered with a ... butt - jointed pieces . Laminations shall be toenailed to supports with 20d ... Joints shall be closely butted over supports or staggered across the deck but within ...
... joints shall occur over framing members and shall be covered with a ... butt - jointed pieces . Laminations shall be toenailed to supports with 20d ... Joints shall be closely butted over supports or staggered across the deck but within ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/mē live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood