Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 10
Page 1-41
... cent spaces by not less than one - hour fire - resistive construction . EXCEPTIONS : 1. The separation between atria and tenant spaces that are not guest rooms , congregate residences or dwelling units may be omitted at three floor ...
... cent spaces by not less than one - hour fire - resistive construction . EXCEPTIONS : 1. The separation between atria and tenant spaces that are not guest rooms , congregate residences or dwelling units may be omitted at three floor ...
Page 1-180
... cent of strengths of similar specimens made with potable water . Strength test comparison shall be made on mortars , identical ex- cept for the mixing water , prepared and tested in accordance with ASTM C 109 ( Compressive Strength of ...
... cent of strengths of similar specimens made with potable water . Strength test comparison shall be made on mortars , identical ex- cept for the mixing water , prepared and tested in accordance with ASTM C 109 ( Compressive Strength of ...
Page 1-276
... cent of the aggregate area of the ceiling in which they are installed . EXCEPTION : The aggregate area need not be limited in a build- ing equipped with an approved automatic sprinkler system complying with UBC Standard 9-1 or 9-3 ...
... cent of the aggregate area of the ceiling in which they are installed . EXCEPTION : The aggregate area need not be limited in a build- ing equipped with an approved automatic sprinkler system complying with UBC Standard 9-1 or 9-3 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood