Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 16
Page xiii
... Connectors and Fasteners 2-293 Section 1649 General 2-400 Section 2319 Wood Shear Walls and Diaphragms .. Division IV 2-294 Section 1650 Location 2-400 Conventional Light - frame Construction .. 2-299 Section 1651 Maintenance 2-400 ...
... Connectors and Fasteners 2-293 Section 1649 General 2-400 Section 2319 Wood Shear Walls and Diaphragms .. Division IV 2-294 Section 1650 Location 2-400 Conventional Light - frame Construction .. 2-299 Section 1651 Maintenance 2-400 ...
Page 1-207
... connectors and fasteners . The installation of timber connectors and fasteners shall be in accordance with the provisions set forth in Division III , Part III . 2304.4.3 Structural glued - laminated timber . The manufacture and ...
... connectors and fasteners . The installation of timber connectors and fasteners shall be in accordance with the provisions set forth in Division III , Part III . 2304.4.3 Structural glued - laminated timber . The manufacture and ...
Page 1-442
... connectors Modulus of elasticity Horizontal shear Joists Joist hangers 2316 Treated ( see FIRE - RETARDANT WOOD ) 2320.8 Treated wood foundations 1810 through 1814 ( Division II ) 2318.4 Trusses , metal plate connectors Masonry , in ...
... connectors Modulus of elasticity Horizontal shear Joists Joist hangers 2316 Treated ( see FIRE - RETARDANT WOOD ) 2320.8 Treated wood foundations 1810 through 1814 ( Division II ) 2318.4 Trusses , metal plate connectors Masonry , in ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood