Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 94
Page 1-61
... CONSTRUCTION AND GENERAL REQUIREMENTS 601.1 General . The requirements of this chapter are for the vari- ous types of construction and represent varying degrees of public safety and resistance to fire . Every building shall be ...
... CONSTRUCTION AND GENERAL REQUIREMENTS 601.1 General . The requirements of this chapter are for the vari- ous types of construction and represent varying degrees of public safety and resistance to fire . Every building shall be ...
Page 1-116
... Construction . Exit enclosures shall be of fire - resis- tive construction as follows : 1. In buildings of other than Type I- or Type II - F.R . construction and less than four stories in height , exit enclosures shall not be of less ...
... Construction . Exit enclosures shall be of fire - resis- tive construction as follows : 1. In buildings of other than Type I- or Type II - F.R . construction and less than four stories in height , exit enclosures shall not be of less ...
Page 1-430
... construction Material ( for construction ) Where required FIREBRICK Definition For chimney lining For fireplaces 303.9 , 305.9 , 307.9 , 308.9 , 310.10 , 408.5 504.6 713.2 , 713.6 713.2 307.6 405.3.3 713 302.2 302.3 , 504.3 708.2 708.2 ...
... construction Material ( for construction ) Where required FIREBRICK Definition For chimney lining For fireplaces 303.9 , 305.9 , 307.9 , 308.9 , 310.10 , 408.5 504.6 713.2 , 713.6 713.2 307.6 405.3.3 713 302.2 302.3 , 504.3 708.2 708.2 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood