Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 11
Page 1-19
... containers or systems and containers or systems pressurized at 15 psi ( 103.4 kPa ) gage or less , and aerosols . 4. Class III - B combustible liquids . 5. Pyrophoric liquids or solids . 6. Class 1 or 2 water - reactive materials . 7 ...
... containers or systems and containers or systems pressurized at 15 psi ( 103.4 kPa ) gage or less , and aerosols . 4. Class III - B combustible liquids . 5. Pyrophoric liquids or solids . 6. Class 1 or 2 water - reactive materials . 7 ...
Page 1-20
... containers shall be constructed in accordance with the requirements for a Group H , Division 2 Occupancy and the following : 1. Rooms in excess of 500 square feet ( 46.5 m2 ) shall have at □ least one exterior exit door approved for ...
... containers shall be constructed in accordance with the requirements for a Group H , Division 2 Occupancy and the following : 1. Rooms in excess of 500 square feet ( 46.5 m2 ) shall have at □ least one exterior exit door approved for ...
Page 1-28
... containers . 13. Fresh fruits in nonplastic trays or containers . 14. Frozen foods . 15. Glass bottles ( empty or filled with nonflammable liquids ) . 16. Gypsum board . 17. Inert pigments . 18. Meats . 19. Metal cabinets . 20. Metal ...
... containers . 13. Fresh fruits in nonplastic trays or containers . 14. Frozen foods . 15. Glass bottles ( empty or filled with nonflammable liquids ) . 16. Gypsum board . 17. Inert pigments . 18. Meats . 19. Metal cabinets . 20. Metal ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood