Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 87
Page 1-158
... designed to support , in addition to all other loads , a uniformly dis- tributed dead load equal to 20 pounds per square foot ( psf ) ( 0.96 kN / m2 ) of floor area . EXCEPTION : Access floor systems shall be designed to support , in ...
... designed to support , in addition to all other loads , a uniformly dis- tributed dead load equal to 20 pounds per square foot ( psf ) ( 0.96 kN / m2 ) of floor area . EXCEPTION : Access floor systems shall be designed to support , in ...
Page 1-159
... designed to resist the loads spe- cified in this section and the special loads set forth in Table 16 - B . 1611.2 Other Loads . Buildings and other structures and por- tions thereof shall be designed to resist all loads due to ...
... designed to resist the loads spe- cified in this section and the special loads set forth in Table 16 - B . 1611.2 Other Loads . Buildings and other structures and por- tions thereof shall be designed to resist all loads due to ...
Page 1-262
... designed to support all loads as specified in Chapter 16 of this code . EXCEPTION : Wood - framed assemblies meeting the require- ments of Section 2320 need not be designed . 2504.2 Wood Framing . Wood stripping or suspended wood ...
... designed to support all loads as specified in Chapter 16 of this code . EXCEPTION : Wood - framed assemblies meeting the require- ments of Section 2320 need not be designed . 2504.2 Wood Framing . Wood stripping or suspended wood ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood