Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 77
Page 1-48
... equipment . The exhaust ca- pacity shall be 200 cubic feet per minute ( 94.4 L / s ) for each lamp connected to the lamp exhaust system , or as recommended by the equipment manufacturer . Auxiliary air may be introduced into the system ...
... equipment . The exhaust ca- pacity shall be 200 cubic feet per minute ( 94.4 L / s ) for each lamp connected to the lamp exhaust system , or as recommended by the equipment manufacturer . Auxiliary air may be introduced into the system ...
Page 1-96
... equipment areas under the exclusive con- trol of a public communication utility agency , provided : 4.1 The equipment areas are separated from the remainder of the building by one - hour fire - resistive occupancy separation ; 4.2 Such ...
... equipment areas under the exclusive con- trol of a public communication utility agency , provided : 4.1 The equipment areas are separated from the remainder of the building by one - hour fire - resistive occupancy separation ; 4.2 Such ...
Page 1-287
... Equipment . When solid - state equipment is used to operate the elevators , the elevator equipment room shall be provided with an independent ventilation or air- conditioning system to prevent overheating of the electrical equipment ...
... Equipment . When solid - state equipment is used to operate the elevators , the elevator equipment room shall be provided with an independent ventilation or air- conditioning system to prevent overheating of the electrical equipment ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/mē live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood