... exceed 50 percent of the yield point under test load . The yield point shall be defined as that point at which an increase in load produces a disproportionate increase in settle- ment . Method 2. It shall not exceed one half of the load ...
... exceed 50 percent of the yield point under test load . The yield point shall be defined as that point at which an increase in load produces a disproportionate increase in settle- ment . Method 2. It shall not exceed one half of the load ...
Page 1-199
... exceed those set forth in Table 21 - N . 2109.5 Lateral Support . Masonry walls shall be laterally sup- ported in either the horizontal or vertical direction not exceeding the intervals set forth in Table 21 - O . Lateral support shall ...
... exceed those set forth in Table 21 - N . 2109.5 Lateral Support . Masonry walls shall be laterally sup- ported in either the horizontal or vertical direction not exceeding the intervals set forth in Table 21 - O . Lateral support shall ...
Page 1-276
... exceed 331/3 percent of the floor area of the room or space shel- tered by the roof when CC1 materials are used and ... exceed 30 square feet ( 2.8 m2 ) . 4. The area of approved plastic materials when used in required means of egress as ...
... exceed 331/3 percent of the floor area of the room or space shel- tered by the roof when CC1 materials are used and ... exceed 30 square feet ( 2.8 m2 ) . 4. The area of approved plastic materials when used in required means of egress as ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/mē live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood