Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 96
Page 1-13
... fire and life hazard . For changes in use , see Section 3405 . SECTION 302 ... resistive construction . 302.3 Types of Occupancy Separations . Occupancy ... construction . 2. A three - hour fire - resistive occupancy separation shall not ...
... fire and life hazard . For changes in use , see Section 3405 . SECTION 302 ... resistive construction . 302.3 Types of Occupancy Separations . Occupancy ... construction . 2. A three - hour fire - resistive occupancy separation shall not ...
Page 1-62
International Conference of Building Officials. 602.5 1. Noncombustible materials . 2. Fire - retardant - treated wood . 3. One - hour fire - resistive construction . 4. Wood panels or similar light construction up to three fourths the ...
International Conference of Building Officials. 602.5 1. Noncombustible materials . 2. Fire - retardant - treated wood . 3. One - hour fire - resistive construction . 4. Wood panels or similar light construction up to three fourths the ...
Page 1-71
... fire - resistive thickness of such wall . 709.3 Exterior Walls . 709.3.1 Extension through attics and concealed spaces . In fire - resistive exterior wall construction , the fire - resistive rating shall be maintained for such walls ...
... fire - resistive thickness of such wall . 709.3 Exterior Walls . 709.3.1 Extension through attics and concealed spaces . In fire - resistive exterior wall construction , the fire - resistive rating shall be maintained for such walls ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood