... fire and smoke within a building and the spread of fire to or from buildings . SECTION 702- DEFINITIONS For the purposes of this chapter , the terms , phrases and words listed in this section and their derivatives shall have the ...
... fire and smoke within a building and the spread of fire to or from buildings . SECTION 702- DEFINITIONS For the purposes of this chapter , the terms , phrases and words listed in this section and their derivatives shall have the ...
Page 1-71
... fire - resistive exterior wall construction , the fire - resistive rating shall be maintained for such walls passing through attic areas or other areas containing concealed spaces . 709.3.2 Vertical fire spread at exterior walls . 709.3 ...
... fire - resistive exterior wall construction , the fire - resistive rating shall be maintained for such walls passing through attic areas or other areas containing concealed spaces . 709.3.2 Vertical fire spread at exterior walls . 709.3 ...
Page 1-72
... fire - resistive integrity of the wall is main- tained in accordance with UBC Standard 7-1 . 709.8 Joints . The ... firestopped at each floor . EXCEPTION : BW gas vents installed in accordance with their listing . Gas vents and ...
... fire - resistive integrity of the wall is main- tained in accordance with UBC Standard 7-1 . 709.8 Joints . The ... firestopped at each floor . EXCEPTION : BW gas vents installed in accordance with their listing . Gas vents and ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood