... Liquid use , dispensing and mixing rooms shall not be located in basements . 307.1.4 Liquid storage rooms . Rooms in which Class I , Class II and Class III - A flammable or combustible liquids are stored in closed containers shall be ...
... Liquid use , dispensing and mixing rooms shall not be located in basements . 307.1.4 Liquid storage rooms . Rooms in which Class I , Class II and Class III - A flammable or combustible liquids are stored in closed containers shall be ...
Page 1-30
... flammable liquids or flammable gases are used or stored . Buildings erected or converted to house high - piled combus- tible stock or aerosols shall comply with the Fire Code . 311.9 Group S , Division 4 Open Parking Garages . 311.9.1 ...
... flammable liquids or flammable gases are used or stored . Buildings erected or converted to house high - piled combus- tible stock or aerosols shall comply with the Fire Code . 311.9 Group S , Division 4 Open Parking Garages . 311.9.1 ...
Page 1-36
... flammable liquids . 16A maximum quantity of 200 pounds ( 90.7 kg ) of solid or 20 gallons ( 75.7 L ) of liquid Class 3 oxidizers may be permitted when such materials are necessary for maintenance purposes or operation of equipment as ...
... flammable liquids . 16A maximum quantity of 200 pounds ( 90.7 kg ) of solid or 20 gallons ( 75.7 L ) of liquid Class 3 oxidizers may be permitted when such materials are necessary for maintenance purposes or operation of equipment as ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood