Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 85
Page 1-118
... grade or shall provide direct access to grade . The exit discharge shall not reenter the exit access . Exterior exit balconies , exterior exit stairways and exterior exit ramps shall not be located in areas where building openings are ...
... grade or shall provide direct access to grade . The exit discharge shall not reenter the exit access . Exterior exit balconies , exterior exit stairways and exterior exit ramps shall not be located in areas where building openings are ...
Page 1-347
... Grade MW except that where subject to severe freezing it shall be Grade SW . 4. Interior clay or shale hollow brick shall be Grade MW with a compressive strength of 2,000 psi ( 13 780 kPa ) on the net area . 2112.4.3 Solid masonry . 1 ...
... Grade MW except that where subject to severe freezing it shall be Grade SW . 4. Interior clay or shale hollow brick shall be Grade MW with a compressive strength of 2,000 psi ( 13 780 kPa ) on the net area . 2112.4.3 Solid masonry . 1 ...
Page 1-408
... " soils engineer . " GRADE is the vertical location of the ground surface . Existing Grade is the grade prior to grading . Finish Grade is the final grade of the site that conforms to the approved plan . Rough Grade is the stage at which ...
... " soils engineer . " GRADE is the vertical location of the ground surface . Existing Grade is the grade prior to grading . Finish Grade is the final grade of the site that conforms to the approved plan . Rough Grade is the stage at which ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood