Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 87
Page 1-133
... inches ( 1219 mm ) minimum , measured from a point 18 inches ( 457 mm ) from the center line of the water closet on the side designated for the installa- tion of grab bars . 2.3 Vanities or lavatories located on the wall behind the ...
... inches ( 1219 mm ) minimum , measured from a point 18 inches ( 457 mm ) from the center line of the water closet on the side designated for the installa- tion of grab bars . 2.3 Vanities or lavatories located on the wall behind the ...
Page 1-143
... inch ( 1.65 mm ) ( No. 16 B.W. gage ) galvanized wire mesh placed over waterproof paper back- ing and anchored directly to stud construction . Two - inch - by - 4 - inch ( 51 mm by 102 mm ) stud spacing shall not exceed 16 inches ( 406 ...
... inch ( 1.65 mm ) ( No. 16 B.W. gage ) galvanized wire mesh placed over waterproof paper back- ing and anchored directly to stud construction . Two - inch - by - 4 - inch ( 51 mm by 102 mm ) stud spacing shall not exceed 16 inches ( 406 ...
Page 1-286
... inches by 54 inches ( 1727 mm by 1372 mm ) . Minimum dis- tance from wall to return panel shall not be less than 51 inches ( 1295 mm ) . EXCEPTION : When approved by the building official , elevators provided in schools , institutions ...
... inches by 54 inches ( 1727 mm by 1372 mm ) . Minimum dis- tance from wall to return panel shall not be less than 51 inches ( 1295 mm ) . EXCEPTION : When approved by the building official , elevators provided in schools , institutions ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood