Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 23
Page 1-64
... laminated or plank inclines as required for floors , where they may be of 1 - inch ( 25 mm ) thickness . Wood stair string- ers shall be a minimum of 3 inches ( 76 mm ) in thickness and not less than 10 inches ( 254 mm ) in depth . In ...
... laminated or plank inclines as required for floors , where they may be of 1 - inch ( 25 mm ) thickness . Wood stair string- ers shall be a minimum of 3 inches ( 76 mm ) in thickness and not less than 10 inches ( 254 mm ) in depth . In ...
Page 1-206
... laminated timber . 2.1 ANSI / AITC Standard A190.1 and ASTM D 3737 , Design and Manufacture of Structural Glued - laminated Timber 2.2 Standard Specifications for Structural Glued - lami- nated Timber of Softwood Species , AITC 117 ...
... laminated timber . 2.1 ANSI / AITC Standard A190.1 and ASTM D 3737 , Design and Manufacture of Structural Glued - laminated Timber 2.2 Standard Specifications for Structural Glued - lami- nated Timber of Softwood Species , AITC 117 ...
Page 1-307
... laminated Timber ASTM D 3737-89a , AITC 500-91 , American Institute of Timber Construction . Prefabricated Wood I - Joists . Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I - Joists ...
... laminated Timber ASTM D 3737-89a , AITC 500-91 , American Institute of Timber Construction . Prefabricated Wood I - Joists . Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I - Joists ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood