Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 69
Page 1-45
... Means of Egress . 404.4.1 General . Each tenant space and the covered mall build- ing shall be provided with means of egress as required by this sec- tion and Chapter 10. Where there is a conflict between the requirements of Chapter 10 ...
... Means of Egress . 404.4.1 General . Each tenant space and the covered mall build- ing shall be provided with means of egress as required by this sec- tion and Chapter 10. Where there is a conflict between the requirements of Chapter 10 ...
Page 1-105
... means of egress as required by this chapter . A means of egress is an exit system that provides a continuous , unobstructed and undiminished path of exit travel from any occupied point in a building or structure to a public way . Such means ...
... means of egress as required by this chapter . A means of egress is an exit system that provides a continuous , unobstructed and undiminished path of exit travel from any occupied point in a building or structure to a public way . Such means ...
Page 1-106
... means of egress as required by this chapter . Where an outdoor area exits only through a building , the occupant load of such outdoor area shall be considered in the design of the means of egress system of that building . 1003.2.2.2.5 ...
... means of egress as required by this chapter . Where an outdoor area exits only through a building , the occupant load of such outdoor area shall be considered in the design of the means of egress system of that building . 1003.2.2.2.5 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/mē live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood