... measured along a direct path of exit travel within a fire - resistive corridor complying with Section 1004.3.4.3.1 serving exit enclosures . The walls of any such exit enclosure shall not be less than 30 feet ( 9144 mm ) , measured in a ...
... measured along a direct path of exit travel within a fire - resistive corridor complying with Section 1004.3.4.3.1 serving exit enclosures . The walls of any such exit enclosure shall not be less than 30 feet ( 9144 mm ) , measured in a ...
Page 1-123
... measured horizontally between the back or backrest of each seat and the front of the seat immediately behind it . The minimum spacing of rows of seats measured from back to back shall be : 1. Twenty - two inches ( 559 mm ) for seats ...
... measured horizontally between the back or backrest of each seat and the front of the seat immediately behind it . The minimum spacing of rows of seats measured from back to back shall be : 1. Twenty - two inches ( 559 mm ) for seats ...
Page 1-133
... measured from the wall behind the water closet . 3.2 Sixty inches ( 1524 mm ) minimum , measured from a point 18 inches ( 457 mm ) from the center line of the water closet on the side designated for the installation of grab bars ...
... measured from the wall behind the water closet . 3.2 Sixty inches ( 1524 mm ) minimum , measured from a point 18 inches ( 457 mm ) from the center line of the water closet on the side designated for the installation of grab bars ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood