Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 89
Page 1-269
... Minimum Thickness3 Minimum Period Moist Curing 48 hours Minimum Interval between Coats 48 hours 48 hours 7 days7 7 PORTLAND CEMENT - LIME PLASTER9 Coat Volume Cement Maximum Volume Lime per Volume Cement Maximum Volume Sand per Combined ...
... Minimum Thickness3 Minimum Period Moist Curing 48 hours Minimum Interval between Coats 48 hours 48 hours 7 days7 7 PORTLAND CEMENT - LIME PLASTER9 Coat Volume Cement Maximum Volume Lime per Volume Cement Maximum Volume Sand per Combined ...
Page 1-286
... minimum clear distance between walls or be- tween wall and door , excluding return panels , shall not be less than 68 inches by 54 inches ( 1727 mm by 1372 mm ) . Minimum dis- tance from wall to return panel shall not be less than 51 ...
... minimum clear distance between walls or be- tween wall and door , excluding return panels , shall not be less than 68 inches by 54 inches ( 1727 mm by 1372 mm ) . Minimum dis- tance from wall to return panel shall not be less than 51 ...
Page 1-397
International Conference of Building Officials. Appendix Chapter 29 MINIMUM PLUMBING FIXTURES TABLE A - 29 - A - MINIMUM PLUMBING FIXTURES1,2,3 For the occupancies listed below , use 30 square feet ( 2.78 m2 ) per occupant for the minimum ...
International Conference of Building Officials. Appendix Chapter 29 MINIMUM PLUMBING FIXTURES TABLE A - 29 - A - MINIMUM PLUMBING FIXTURES1,2,3 For the occupancies listed below , use 30 square feet ( 2.78 m2 ) per occupant for the minimum ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood