Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 40
Page 1-82
... nails . Approved metal fastener grips used with nails at vertical butt joints along studs . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers of 3/8 " ( 9.5 mm ) regular gypsum wallboard ' each side ...
... nails . Approved metal fastener grips used with nails at vertical butt joints along studs . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers of 3/8 " ( 9.5 mm ) regular gypsum wallboard ' each side ...
Page 1-83
... nails 12 " ( 305 mm ) on center . The face layer is placed horizontally and attached with 8d box nails 8 " ( 203 mm ) on center at joints and 12 " ( 305 mm ) on center elsewhere . The exterior face has a base layer of 5/8 " ( 15.9 mm ) ...
... nails 12 " ( 305 mm ) on center . The face layer is placed horizontally and attached with 8d box nails 8 " ( 203 mm ) on center at joints and 12 " ( 305 mm ) on center elsewhere . The exterior face has a base layer of 5/8 " ( 15.9 mm ) ...
Page 1-270
... NAILS TO WOOD x 25.4 for mm Nails3 Screws4 16 P P Horizontal 7 24 NP P 1/2 16 P P Vertical 8 24 P P 16 P P Horizontal 7 24 NP P 518 16 P P Vertical 8 24 P P ( Column headings as above ) 16 No. 13 gage , 13/8 " long , 19/64 " head ...
... NAILS TO WOOD x 25.4 for mm Nails3 Screws4 16 P P Horizontal 7 24 NP P 1/2 16 P P Vertical 8 24 P P 16 P P Horizontal 7 24 NP P 518 16 P P Vertical 8 24 P P ( Column headings as above ) 16 No. 13 gage , 13/8 " long , 19/64 " head ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood