Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 94
Page 1-6
... portion of the building for which the certificate is issued . 5. A statement that the described portion of the building has been inspected for compliance with the requirements of this code for the group and division of occupancy and the ...
... portion of the building for which the certificate is issued . 5. A statement that the described portion of the building has been inspected for compliance with the requirements of this code for the group and division of occupancy and the ...
Page 1-33
... portion of a building having an assembly room with an occupant load of 1,000 or more and a legitimate stage . A building or portion of a building having an assembly room with an occupant load of less than 1,000 and a legitimate stage ...
... portion of a building having an assembly room with an occupant load of 1,000 or more and a legitimate stage . A building or portion of a building having an assembly room with an occupant load of less than 1,000 and a legitimate stage ...
Page 1-111
... portion of the means of egress system shall comply with the applicable design requirements of Section 1004.2 . For the purposes of Section 1004.2 , the term " exit - access doorway " shall mean the point of entry to one portion of the ...
... portion of the means of egress system shall comply with the applicable design requirements of Section 1004.2 . For the purposes of Section 1004.2 , the term " exit - access doorway " shall mean the point of entry to one portion of the ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood