Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 50
Page 1-153
... sheathing with battens , or spaced sheathing3 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL ( 33.3 % Slope ) AND OVER Spaced structural sheathing boards or solid roof sheathing . Solid sheathing one layer of Type 30 felt lapped 2 inches ( 51 ...
... sheathing with battens , or spaced sheathing3 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL ( 33.3 % Slope ) AND OVER Spaced structural sheathing boards or solid roof sheathing . Solid sheathing one layer of Type 30 felt lapped 2 inches ( 51 ...
Page 1-210
... sheathing , joints shall occur over framing members and shall be covered with a continuous wood batt ; or joints ... SHEATHING 2312.1 Structural Floor Sheathing . Structural floor sheathing shall be designed in accordance with the ...
... sheathing , joints shall occur over framing members and shall be covered with a continuous wood batt ; or joints ... SHEATHING 2312.1 Structural Floor Sheathing . Structural floor sheathing shall be designed in accordance with the ...
Page 1-393
... sheathing at one face , interior main cross - stud partitions with sheathing at each face . The values for sheathing are listed in order of increased capacity . Sheathing with a capacity greater than required may be substituted for the ...
... sheathing at one face , interior main cross - stud partitions with sheathing at each face . The values for sheathing are listed in order of increased capacity . Sheathing with a capacity greater than required may be substituted for the ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood