Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 92
Page 1-93
... smoke - control systems and smoke and heat venting systems . For requirements on fire alarm systems , see the following : SECTION 303.9 SUBJECT Group A , Divisions 1 and 2 Occupancies 305.2.3 , 305.9 Group E Occupancies 307.9 Group H ...
... smoke - control systems and smoke and heat venting systems . For requirements on fire alarm systems , see the following : SECTION 303.9 SUBJECT Group A , Divisions 1 and 2 Occupancies 305.2.3 , 305.9 Group E Occupancies 307.9 Group H ...
Page 1-100
... Smoke - control systems shall be activated as follows : 1. Mechanical smoke - control systems , using the pressuriza- tion method , serving buildings having no occupied floor more than 300 feet ( 91 440 mm ) above or 75 feet ( 22 860 mm ) ...
... Smoke - control systems shall be activated as follows : 1. Mechanical smoke - control systems , using the pressuriza- tion method , serving buildings having no occupied floor more than 300 feet ( 91 440 mm ) above or 75 feet ( 22 860 mm ) ...
Page 1-310
... smoke - detection system . 321.2 Wet Standpipes . Every building in a detention or correc- tional facility , housing 50 or more inmates , shall be provided with Class II standpipes with hoses , conforming to the provisions of Chapter 9 ...
... smoke - detection system . 321.2 Wet Standpipes . Every building in a detention or correc- tional facility , housing 50 or more inmates , shall be provided with Class II standpipes with hoses , conforming to the provisions of Chapter 9 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood