Uniform Building Code, Volume 1International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 94
Page 1-70
... spaces under the flooring that will ex- ceed 100 square feet ( 9.3 m2 ) in area and such space shall be filled solidly under all permanent partitions so that there is no communi- cation under the flooring between adjoining rooms ...
... spaces under the flooring that will ex- ceed 100 square feet ( 9.3 m2 ) in area and such space shall be filled solidly under all permanent partitions so that there is no communi- cation under the flooring between adjoining rooms ...
Page 1-132
... space . A 30 - inch - by - 48 - inch ( 762 mm by 1219 mm ) minimum clear floor space positioned for forward or parallel approach shall be provided at each accessible operating control . Where a parallel approach is provided to an ...
... space . A 30 - inch - by - 48 - inch ( 762 mm by 1219 mm ) minimum clear floor space positioned for forward or parallel approach shall be provided at each accessible operating control . Where a parallel approach is provided to an ...
Page 1-133
... space . 2. Forward approach . 2.1 Sixty - six inches ( 1676 mm ) minimum , measured from the wall behind the water closet . 2.2 Forty - eight inches ( 1219 mm ) minimum , measured from a point 18 inches ( 457 mm ) from the center line ...
... space . 2. Forward approach . 2.1 Sixty - six inches ( 1676 mm ) minimum , measured from the wall behind the water closet . 2.2 Forty - eight inches ( 1219 mm ) minimum , measured from a point 18 inches ( 457 mm ) from the center line ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 1-7 |
UBC Standard 72 Fire Tests of Door Assemblies | 1-68 |
UBC Standard 2111 | 1-94 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accessible aggregate aisle applied approved area of refuge ASTM automatic sprinkler system B.W. gage braced wall lines building official building or structure ceiling cement combustible comply concrete conform corridor Division 3 Occupancies doors dwelling units elevator equipment exceed EXCEPTION exit-access exterior walls fire assembly Fire Code fire-resistive construction fire-resistive rating floor area grade Group H grout gypsum hazardous height inches inspection installed insulation joists kN/m² live load located masonry materials maximum means of egress minimum N/C less nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels percent perlite portion reinforcement requirements of Section roof rooms Select Structural sheathing slope smoke smoke detector space specified in Chapter specified in Section square feet stairways standpipes steel storage story studs surface Table tested thickness tion Type UBC Standard Uniform Building Code units vertical veneer ventilation vermiculite vertical in 12 wallboard water closet width wire wood